34. AC TIMING PARAMETERS AND DIAGRAMS

Capacitive test loads are 40pF for bus signals, 20pF for all others.

34.1 Multipexed Bus AC Characteristics

AC CHARACTERISTICS–MULTIPLEXED PARALLEL PORT (MUX = 1)
(0

°

C to +70

°

C; V

DD

= 3.3V

±

5% for DS21Q55;

-40

°

C to +85

°

C; V

DD

= 3.3V

±

5% for DS21Q55N)

PARAMETER

SYMBOL

MIN

TYP

MAX

UNITS

NOTES

Cycle Time

T

CYC

200

ns

Pulse Width, DS Low or RD*
High

PW

EL

100

ns

Pulse Width, DS High or RD*
Low

PW

EH

100

ns

Input Rise/Fall Times

T

R

, t

F

20

ns

R/W* Hold Time

T

RWH

10

ns

R/W* Setup Time Before DS
High

T

RWS

50

ns

CS* Setup Time Before DS,
WR* or RD* Active

t

CS

20

ns

CS* Hold Time

t

CH

0

ns

Read Data Hold Time

T

DHR

10

50

ns

Write Data Hold Time

T

DHW

5

ns

Muxed Address Valid to AS or
ALE Fall

T

ASL

15

ns

Muxed Address Hold Time

T

AHL

10

ns

Delay Time DS, WR*, or RD*
to AS or ALE Rise

T

ASD

20

ns

Pulse Width AS or ALE High

PW

ASH

30

ns

Delay Time, AS or ALE to DS,
WR* or RD*

T

ASED

10

ns

Output Data Delay Time from
DS or RD*

T

DDR

80

ns

Data Setup Time

T

DSW

50

ns

See Figures 37-1 to 37-3