Register Name:

RSCSE1 , RSCSE2 , RSCSE3 , RSCSE4

Register Description:

Receive Signaling Change Of State Interrupt Enable

Register Address:

3Ch, 3Dh, 3Eh, 3Fh

(MSB)

(LSB)

CH8

CH7

CH6

CH5

CH4

CH3

CH2

CH1

RSCSE1

CH16

CH15

CH14

CH13

CH12

CH11

CH10

CH9

RSCSE2

CH24

CH23

CH22

CH21

CH20

CH19

CH18

CH17

RSCSE3

CH30

CH29

CH28

CH27

CH26

CH25

RSCSE4


Setting any of the CH1 through CH30 bits in the RSCSE1 through RSCSE4 registers will cause an
interrupt when that channel’s signaling data changes state.


Register Name:

RSINFO1, RSINFO2, RSINFO3, RSINFO4

Register Description:

Receive Signaling Change Of State Information

Register Address:

38h, 39h, 3Ah, 3Bh

(MSB)

(LSB)

CH8

CH7

CH6

CH5

CH4

CH3

CH2

CH1

RSINFO1

CH16

CH15

CH14

CH13

CH12

CH11

CH10

CH9

RSINFO2

CH24

CH23

CH22

CH21

CH20

CH19

CH18

CH17

RSINFO3

CH30

CH29

CH28

CH27

CH26

CH25

RSINFO4

When a channel’s signaling data changes state, the respective bit in registers RSINFO1-4 will be set. If
the channel was also enabled as an interrupt source by setting the appropriate bit in RSCSE1–4, an
interrupt is generated. The bit will remain set until read.