E1 alarm criteria table 11-2 – Maxim Integrated DS21Q55 User Manual

Page 58

Advertising
background image

Product Preview

DS21Q55

58 of 248

012103

Please contact

[email protected]

or search

http://www.maxim-ic.com

for updated

information.

E1 ALARM CRITERIA Table 11-2

ALARM

SET CRITERIA

CLEAR CRITERIA

ITU

SPEC.

RLOS

An RLOS condition exists on power-
up prior to initial synchronization,
when a re-sync criteria has been met,
or when a manual re-sync has been
initiated via E1RCR1.0

RCL

255 or 2048 consecutive zeros
received as determined by E1RCR2.0

In 255-bit times, at least 32
ones are received

G.775/G.962

RRA

Bit 3 of nonalign frame set to one for
three consecutive occasions

Bit 3 of nonalign frame set
to zero for three consecutive
occasions

O.162

2.1.4

RUA1

Fewer than three zeros in two frames
(512 bits)

More than two zeros in two
frames (512 bits)

O.162

1.6.1.2

RDMA

Bit 6 of timeslot 16 in frame 0 has
been set for two consecutive
multiframes

V52LNK

Two out of three Sa7 bits are zero

G.965

Advertising