Maxim Integrated DS21Q55 User Manual

Page 84

Advertising
background image

Product Preview

DS21Q55

84 of 248

012103

Please contact

[email protected]

or search

http://www.maxim-ic.com

for updated

information.


Register Name:

RS1 to RS12

Register Description:

Receive Signaling Registers (T1 Mode, ESF Format)

Register Address:

60h to 6Bh


(MSB)

(LSB)

CH2-A

CH2-B

CH2-C

CH2-D

CH1-A

CH1-B

CH1-C

CH1-D

RS1

CH4-A

CH4-B

CH4-C

CH4-D

CH3-A

CH3-B

CH3-C

CH3-D

RS2

CH6-A

CH6-B

CH6-C

CH6-D

CH5-A

CH5-B

CH5-C

CH5-D

RS3

CH8-A

CH8-B

CH8-C

CH8-D

CH7-A

CH7-B

CH7-C

CH7-D

RS4

CH10-A

CH10-B

CH10-C

CH10-D

CH9-A

CH9-B

CH9-C

CH9-D

RS5

CH12-A

CH12-B

CH12-C

CH12-D

CH11-A

CH11-B

CH11-C

CH11-D

RS6

CH14-A

CH14-B

CH14-C

CH14-D

CH13-A

CH13-B

CH13-C

CH13-D

RS7

CH16-A

CH16-B

CH16-C

CH16-D

CH15-A

CH15-B

CH15-C

CH15-D

RS8

CH18-A

CH18-B

CH18-C

CH18-D

CH17-A

CH17-B

CH17-C

CH17-D

RS9

CH20-A

CH20-B

CH20-C

CH20-D

CH19-A

CH19-B

CH19-C

CH19-D

RS10

CH22-A

CH22-B

CH22-C

CH22-D

CH21-A

CH21-B

CH21-C

CH21-D

RS11

CH24-A

CH24-B

CH24-C

CH24-D

CH23-A

CH23-B

CH23-C

CH23-D

RS12




Register Name:

RS1 to RS12

Register Description:

Receive Signaling Registers (T1 Mode, D4 Format)

Register Address:

60h to 6Bh


(MSB)

(LSB)

CH2-A

CH2-B

CH2 -A

CH2 -B

CH1-A

CH1-B

CH1 -A

CH1 -B

RS1

CH4-A

CH4-B

CH4 -A

CH4 -B

CH3-A

CH3-B

CH3 -A

CH3 -B

RS2

CH6-A

CH6-B

CH6 -A

CH6 -B

CH5-A

CH5-B

CH5 -A

CH5 -B

RS3

CH8-A

CH8-B

CH8-A

CH8 -B

CH7-A

CH7-B

CH7 -A

CH7 -B

RS4

CH10-A

CH10-B

CH10-A

CH10-B

CH9-A

CH9-B

CH9 -A

CH9 -B

RS5

CH12-A

CH12-B

CH12-A

CH12-B

CH11-A

CH11-B

CH11-A

CH11-B

RS6

CH14-A

CH14-B

CH14-A

CH14-B

CH13-A

CH13-B

CH13-A

CH13-B

RS7

CH16-A

CH16-B

CH16-A

CH16-B

CH15-A

CH15-B

CH15-A

CH15-B

RS8

CH18-A

CH18-B

CH18-A

CH18-B

CH17-A

CH17-B

CH17-A

CH17-B

RS9

CH20-A

CH20-B

CH20-A

CH20-B

CH19-A

CH19-B

CH19-A

CH19-B

RS10

CH22-A

CH22-B

CH22-A

CH22-B

CH21-A

CH21-B

CH21-A

CH21-B

RS11

CH24-A

CH24-B

CH24-A

CH24-B

CH23-A

CH23-B

CH23-A

CH23-B

RS12

Note:

In D4 format, TS1-TS12 contain signaling data for two frames. Bold type indicates data fo r second frame.

Advertising