25.4 BERT Error Counter

Once BERT has achieved synchronization, this 24-bit counter will increment for each data bit received in
error. Toggling the LC control bit in BC1 can clear this counter. This counter saturates when full and will
set the BECO status bit.



Register Name:

BEC1

Register Description:

BERT Error Count Register 1

Register Address:

E7h


Bit #

7

6

5

4

3

2

1

0

Name

EC7

EC6

EC5

EC4

EC3

EC2

EC1

EC0

Default

0

0

0

0

0

0

0

0


Bits 0 to 7/Error Counter Bits 0 to 7 (EC0 to EC7). EC0 is the LSB of the 24-bit counter.


Register Name:

BEC2

Register Description:

BERT Error Count Register 2

Register Address:

E8h


Bit #

7

6

5

4

3

2

1

0

Name

EC15

EC14

EC13

EC12

EC11

EC10

EC9

EC8

Default

0

0

0

0

0

0

0

0


Bits 0 to 7/Error Counter Bits 8 to 15 (EC8 to EC15).


Register Name:

BEC3

Register Description:

BERT Error Count Register 3

Register Address:

E9h


Bit #

7

6

5

4

3

2

1

0

Name

EC23

EC22

EC21

EC20

EC19

EC18

EC17

EC16

Default

0

0

0

0

0

0

0

0


Bits 0 to 7/Error Counter Bits 16 to 23 (EC16 to EC23). EC23 is the MSB of the 24-bit counter.