DS21Q55

238 of 248

012103

Please contact

[email protected]

or search

http://www.maxim-ic.com

for updated

information.

MOTOROLA BUS READ TIMING (BTS = 1 / MUX = 0) Figure 37-6





MOTOROLA BUS WRITE TIMING (BTS = 1 / MUX = 0) Figure 37-7


Address Valid

Data Valid

A0 to A7

D0 to D7

R/W*

CS*

DS*

0ns min.

0ns min.

75ns max.

0ns min.

5ns min. / 20ns max.

t1

t2

t3

t4

t5

Address Valid

A0 to A7

D0 to D7

R/W*

CS*

DS*

0ns min.

0ns min.

75ns min.

0ns min.

10ns
min.

10ns
min.

t1

t2

t6

t4

t7 t8