Maxim Integrated DS21Q55 User Manual

Page 93

Advertising
background image

Product Preview

DS21Q55

93 of 248

012103

Please contact

[email protected]

or search

http://www.maxim-ic.com

for updated

information.

15.2.2 Software Signaling Insertion Enable Registers, E1 CAS Mode
In E1 CAS mode, the CAS signaling alignment/alarm byte can be sourced from the transmit signaling
registers along with the signaling data.


Register Name:

SSIE1

Register Description:

Software Signaling Insertion Enable 1

Register Address:

08h


Bit #

7

6

5

4

3

2

1

0

Name

CH7

CH6

CH5

CH4

CH3

CH2

CH1

UCAW

Default

0

0

0

0

0

0

0

0


Bit 0/Upper CAS Align/Alarm Word (UCAW). Selects the upper CAS align/alarm pattern (0000) to be sourced from the
upper 4 bits of the TS1 register.

0 = do not source the upper CAS align/alarm pattern from the TS1 register
1 = source the upper CAS align/alarm pattern from the TS1 register


Bits 1 to 7/Software Signaling Insertion Enable for Channels 1 to 7 (CH1 to CH7 ).
These bits determine which channels
are to have signaling inserted form the Transmit Signaling registers.

0 = do not source signaling data from the TSx registers for this channel
1 = source signaling data from the TSx registers for this channel


Register Name:

SSIE2

Register Description:

Software Signaling Insertion Enable 2

Register Address:

09h


Bit #

7

6

5

4

3

2

1

0

Name

CH15

CH14

CH13

CH12

CH11

CH10

CH9

CH8

Default

0

0

0

0

0

0

0

0


Bits 0 to 7/Software Signaling Insertion Enable for Channels 8 to 15 (CH8 to CH15). These bits determine which channels
are to have signaling inserted form the transmit signaling registers.

0 = do not source signaling data from the TS registers for this channel
1 = source signaling data from the TS registers for this channel

Advertising