8. T1 FRAMER/FORMATTER CONTROL REGISTERS

The T1 framer portion of the DS21Q55 is configured via a set of nine control registers. Typically, the
control registers are only accessed when the system is first powered up. Once the device has been
initialized, the control registers will only need to be accessed when there is a change in the system
configuration. There are two receive-control registers (T1RCR1 and T1RCR2), two transmit control
registers (T1TCR1 and T1TCR2), and a common control register (T1CCR1). Each of these registers is
described in this section.

8.1 T1 Control Registers


Register Name:

T1RCR1

Register Description:

T1 Receive Control Register 1

Register Address:

03h


Bit #

7

6

5

4

3

2

1

0

Name

-

ARC

OOF1

OOF2

SYNCC

SYNCT

SYNCE

RESYNC

Default

0

0

0

0

0

0

0

0


Bit 0/Resynchronize (RESYNC). When toggled from low to high, a resynchronization of the receive side framer is initiated.
Must be cleared and set again for a subsequent resync.

Bit 1/Sync Enable (SYNCE).

0 = auto resync enabled
1 = auto resync disabled

Bit 2/Sync Time (SYNCT).

0 = qualify 10 bits
1 = qualify 24 bits


Bit 3/Sync Criteria (SYNCC).

In D4 Framing Mode.
0 = search for Ft pattern, then search for Fs pattern
1 = cross couple Ft and Fs pattern
In ESF Framing Mode.
0 = search for FPS pattern only
1 = search for FPS and verify with CRC6


Bits 4 to 5/Out Of Frame Select Bits (OOF2, OOF1).


OOF2

OOF1

OUT OF FRAME CRITERIA

0

0

2/4 frame bits in error

0

1

2/5 frame bits in error

1

0

2/6 frame bits in error

1

1

2/6 frame bits in error


Bit 6/Auto Resync Criteria (ARC).

0 = resync on OOF or RCL event
1 = resync on OOF only


Bit 7/Unused, must be set to zero for proper operation.