3 frames out of sync count register (foscr) – Maxim Integrated DS21Q55 User Manual

Page 76

Advertising
background image

Product Preview

DS21Q55

76 of 248

012103

Please contact

[email protected]

or search

http://www.maxim-ic.com

for updated

information.


Register Name:

PCVCR1

Register Description:

Path Code Violation Count Register 1

Register Address:

44h


Bit #

7

6

5

4

3

2

1

0

Name

PCVC15

PCVC14

PCVC13

PCVC12

PCVC11

PCVC10

PCVC9

PCVC8

Default

0

0

0

0

0

0

0

0


Bits 0 to 7/Path Code Violation Counter Bits 8 to 15 (PCVC8 to PCVC15). PCVC15 is the MSB of the 16-bit path code
violation count.


Register Name:

PCVCR2

Register Description:

Path Code Violation Count Register 2

Register Address:

45h


Bit #

7

6

5

4

3

2

1

0

Name

PCVC7

PCVC6

PCVC5

PCVC4

PCVC3

PCVC2

PCVC1

PCVC0

Default

0

0

0

0

0

0

0

0


Bits 0 to 7/Path Code Violation Counter Bits 0 to 7 (PCVC0 to PCVC7). PCVC0 is the LSB of the 16-bit path code
violation count.


13.3 Frames Out Of Sync Count Register (FOSCR)


T1 Operation

The FOSCR is used to count the number of multiframes that the receive synchronizer is out of sync. This
number is useful in ESF applications needing to measure the parameters loss of frame count (LOFC) and
ESF error events as described in AT&T publication TR54016. When the FOSCR is operated in this
mode, it is not disabled during receive loss of synchronization (RLOS = 1) conditions. The FOSCR has
alternate operating mode whereby it will count either errors in the Ft framing pattern (in the D4 mode) or
errors in the FPS framing pattern (in the ESF mode). When the FOSCR is operated in this mode, it is
disabled during receive loss of synchronization (RLOS = 1) conditions. See Table 15-4 for a detailed
description of what the FOSCR is capable of counting.

T1 FRAMES OUT OF SYNC COUNTING ARRANGEMENTS Table 15-4

FRAMING MODE

(T1RCR1.3)

COUNT MOS OR F-BIT ERRORS

(ERCNT.1)

WHAT IS COUNTED IN THE

FOSCRs

D4

MOS

Number of Multiframes Out of Sync

D4

F-Bit

Errors in the Ft Pattern

ESF

MOS

Number of Multiframes Out of Sync

ESF

F-Bit

Errors in the FPS Pattern

E1 Operation
The FOSCR counts word errors in the frame alignment signal in timeslot 0. This counter is disabled when
RLOS is high. FAS errors will not be counted when the framer is searching for FAS alignment and/or
synchronization at either the CAS or CRC4 multiframe level. Since the maximum FAS word error count
in a one-second period is 4000, this counter cannot saturate.

Advertising