T1 ALARM CRITERIA Table 10-1

ALARM

SET CRITERIA

CLEAR CRITERIA

Blue Alarm (AIS) (Note 1)

Over a 3ms window, five or fewer
zeros are received

Over a 3ms window, six or more zeros are
received

Yellow Alarm (RAI)

D4 Bit-2 Mode (T1RCR2.0 = 0)



D4 12th F-bit Mode (T1RCR2.0 = 1;
this mode is also referred to as the
“Japanese Yellow Alarm”)

ESF Mode



Bit 2 of 256 consecutive channels
is set to zero for at least 254
occurrences

12th framing bit is set to one for
two consecutive occurrences


16 consecutive patterns of 00FF
appear in the FDL



Bit 2 of 256 consecutive channels is set to
zero for less than 254 occurrences


12th framing bit is set to zero for two
consecutive occurrences


14 or fewer patterns of 00FF hex out of 16
possible appear in the FDL

Red Alarm (LRCL) (Also referred to
as Loss Of Signal)

192 consecutive zeros are
received

14 or more ones out of 112 possible bit
positions are received, starting with the
first one received

NOTES:

1) The definition of blue alarm (or alarm indication signal) is an unframed, all-ones signal. Blue alarm

detectors should be able to operate properly in the presence of a 10E-3 error rate, and they should not
falsely trigger on a framed, all-ones signal. The blue alarm criteria in the DS21Q55 has been set to
achieve this performance. It is recommended that the RBL bit be qua lified with the RLOS bit.

2) ANSI specifications use a different nomenclature than this data sheet does; the following terms are

equivalent:

RBL = AIS
RCL = LOS
RLOS = LOF
RYEL = RAI