Motorola ColdFire MCF5281 User Manual

Page 476

Advertising
background image

FlexCAN

25-6

Freescale Semiconductor

Table 25-2. Common Extended/Standard Format Frames

Field

Description

Time Stamp

Contains a copy of the high byte of the free running timer, which is captured at the beginning of the
identifier field of the frame on the CAN bus.

Code

Refer to

Table 25-3

and

Table 25-4

.

Rx Length

Length (in bytes) of the Rx data stored in offset 0x6 through 0xD of the buffer. This field is written by
the FlexCAN module, copied from the data length code (DLC) field of the received frame.

Tx Length

Length (in bytes) of the data to be transmitted, located in offset 0x6 through 0xD of the buffer. This
field is written by the CPU, and is used as the DLC field value. If remote transmission request (RTR))
= 1, the frame is a remote frame and will be transmitted without the data field, regardless of the value
in Tx length.

Data

This field can store up to eight data bytes for a frame. For Rx frames, the data is stored as it is
received from the bus. For Tx frames, the CPU provides the data to be transmitted within the frame.

Reserved

This word entry field (16 bits) should not be accessed by the CPU.

Table 25-3. Message Buffer Codes for Receive Buffers

Rx Code

Before Rx

New Frame

Description

Rx Code

After Rx

New Frame

Comment

0000

NOT ACTIVE — message buffer is not active.

0100

EMPTY — message buffer is active and empty.

0010

0010

FULL — message buffer is full.

0110

If a CPU read occurs before
the new frame, new receive
code is 0010.

0110

OVERRUN — second frame was received into a full
buffer before the CPU read the first one.

0101

1

1

For transmit message buffers, upon read, the BUSY bit should be ignored.

BUSY — message buffer is now being filled with a new
receive frame. This condition will be cleared within 20
cycles.

0010

An empty buffer was filled.

0011

1

0110

A full buffer was filled.

0111

1

0110

An overrun buffer was filled.

Table 25-4. Message Buffer Codes for Transmit Buffers

RTR

Initial Tx Code

Description

Code After

Successful

Transmission

X

1000

Message buffer not ready for transmit.

0

1100

Data frame to be transmitted once, unconditionally.

1000

1

1100

Remote frame to be transmitted once, and message buffer
becomes an Rx message buffer for data frames.

0100

0

1010

1

1

When a matching remote request frame is detected, the code for such a message buffer is changed to be 1110.

Data frame to be transmitted only as a response to a remote
frame.

1010

0

1110

Data frame to be transmitted only once, unconditionally, and
then only as a response to remote frame.

1010

MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3

Advertising