Debug Support

30-28

Freescale Semiconductor

NOTE

DUMP

does not check for a valid address; it is a valid command only when

preceded by

NOP

,

READ

, or another

DUMP

command. Otherwise, an illegal

command response is returned.

NOP

can be used for intercommand padding

without corrupting the address pointer.

The size field is examined each time a

DUMP

command is processed, allowing the operand size to be

dynamically altered.

Command/Result Formats:

15

12

11

8

7

4

3

0

Byte

Command

0x1

0xD

0x0

0x0

Result

X

X

X

X

X

X

X

X

D[7:0]

Word

Command

0x1

0xD

0x4

0x0

Result

D[15:0]

Longword

Command

0x1

0xD

0x8

0x0

Result

D[31:16]

D[15:0]

Figure 30-25.

DUMP

Command/Result Formats