17 debug ac timing specifications, 17debug ac timing specifications -27 – Motorola ColdFire MCF5281 User Manual

Page 711

Advertising
background image

Electrical Characteristics

Freescale Semiconductor

33-27

Figure 33-19. TRST Timing

Figure 33-20. BKPT Timing

33.17 Debug AC Timing Specifications

Table 33-28

lists specifications for the debug AC timing parameters shown in

Figure 33-22

.

Figure 33-21

shows real-time trace timing for the values in

Table 33-28

.

Table 33-28. Debug AC Timing Specification

Num

Characteristic

Min

Max

Units

D1

PST, DDATA to TCLK setup

5

ns

D2

TCLK to PST, DDATA hold

2

ns

D3

DSI-to-DSCLK setup

1

CLKOUT

cycles

D4

1

1

DSCLK and DSI are synchronized internally. D4 is measured from the
synchronized DSCLK input relative to the rising edge of CLKOUT.

DSCLK-to-DSO hold

4

CLKOUT

cycles

D5

DSCLK cycle time

5

CLKOUT

cycles

D6

BKPT input data setup time to
CLKOUT Rise

5.0

ns

D7

BKPT input data hold time to
CLKOUT Rise

2.0 ns

D8

CLKOUT high to BKPT high Z

0.0

10.0

ns

TCLK

TRST

14

13

Input Data Valid

CLKOUT

BKPT

(Input)

V

IL

V

IH

15

16

B1b

B2b

17

MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3

Advertising