3 command set descriptions, 3 command set descriptions -22, Section 30.5.3.3, “command set descriptions – Motorola ColdFire MCF5281 User Manual

Page 640: These commands contain a 5-bit field, drc, that, Section 30.5.3.3, “command, Set descriptions, Figure 30-16, Shows serial bus traf

Advertising
background image

Debug Support

30-22

Freescale Semiconductor

Figure 30-16. Command Sequence Diagram

The sequence is as follows:

In cycle 1, the development system command is issued (

READ

in this example). The debug module

responds with either the low-order results of the previous command or a command complete status
of the previous command, if no results are required.

In cycle 2, the development system supplies the high-order 16 address bits. The debug module
returns a not-ready response unless the received command is decoded as unimplemented, which is
indicated by the illegal command encoding. If this occurs, the development system should
retransmit the command.

NOTE

A not-ready response can be ignored except during a memory-referencing
cycle. Otherwise, the debug module can accept a new serial transfer after 32
processor clock periods.

In cycle 3, the development system supplies the low-order 16 address bits. The debug module
always returns a not-ready response.

At the completion of cycle 3, the debug module initiates a memory read operation. Any serial
transfers that begin during a memory access return a not-ready response.

Results are returned in the two serial transfer cycles after the memory access completes. For any
command performing a byte-sized memory read operation, the upper 8 bits of the response data are
undefined and the referenced data is returned in the lower 8 bits. The next command’s opcode is
sent to the debug module during the final transfer. If a memory or register access is terminated with
a bus error, the error status (S = 1, DATA = 0x0001) is returned instead of result data.

30.5.3.3

Command Set Descriptions

The following sections describe the commands summarized in

Table 30-17

.

XXX

’NOT READY’

READ (LONG)

???

MS ADDR

’NOT READY’

LS ADDR

’NOT READY’

NEXT CMD

’NOT READY’

NEXT CMD

’NOT READY’

NEXT CMD

LS RESULT

Commands transmitted to the debug module

Command code transmitted during this cycle

High-order 16 bits of memory address

Low-order 16 bits of memory address

Non-serial-related

Next

Command

Code

Sequence taken if operation
has not completed

activity

READ

MEMORY

LOCATION

XXX

BERR

XXX

MS RESULT

XXX

’ILLEGAL’

Responses from the debug module

Results from previous command

Sequence taken if illegal command
is received by debug module

Data used from this transfer

Sequence taken if bus error
occurs on memory access

High- and low-order 16 bits of result

MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3