Parameters – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 101

Advertising
background image

5 - 12

5. PARAMETERS

Classifi-

cation

No. Symbol

Name and Function

Initial

Value

Unit

Setting

Range

41

500

42

0000

43

0111

44

20

45

50

46

0

47

0

48

For manufacturer setting
Do not change this value by any means.

0

49

*CDP

Gain changing selection
Select the gain changing condition. (Refer to section 7.5)

Gain changing selection
Under any of the following conditions, the gains
change on the basis of the parameter No. 52 to 55
settings.
0: Invalid
1: Control instructions from a controller.
2: Command frequency (Parameter No.50
setting)
3: Droop pulse value (Parameter No.50 setting)
4: Servo motor speed (Parameter No.50 setting)

0 0 0

0000

Refer to

Name

and

function

column.

50

CDS

Gain changing condition
Used to set the value of gain changing condition (command
frequency, droop pulses, servo motor speed) selected in parameter
No. 49. The set value unit changes with the changing condition item.
(Refer to section 7.5)

10

kpps

pulse
r/min

0

to

9999

51

CDT

Gain changing time constant
Used to set the time constant at which the gains will change in
response to the conditions set in parameters No. PB26 and PB27.
(Refer to section 7.6.)

1

ms

0

to

100

52

GD2B Ratio of load inertia moment to servo motor inertia moment 2

Used to set the ratio of load inertia moment to servo motor inertia
moment when gain changing is valid.

7.0

times

0

to

300.0

53

PG2B Position control gain 2 changing ratio

Used to set the ratio of changing the position control gain 2 when
gain changing is valid.
Made valid when auto tuning is invalid.

100

%

10

to

200

54

VG2B Speed control gain 2 changing ratio

Used to set the ratio of changing the speed control gain 2 when gain
changing is valid.
Made valid when auto tuning is invalid.

100

%

10

to

200

55

VICB

Speed integral compensation changing ratio
Used to set the ratio of changing the speed integral compensation
when gain changing is valid. Made valid when auto tuning is
invalid.

100

%

50

to

1000

56

0000

57

0000

58

0000

E

xpa

n

si

on

pa

ra

m

et

er 2

59

For manufacturer setting
Do not change this value by any means.

0000

Advertising