2 auxiliary equipment, 1 recommended wires, Options and auxiliary equipment – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 205

Advertising
background image

12 - 46

12. OPTIONS AND AUXILIARY EQUIPMENT

12.2 Auxiliary equipment

Always use the devices indicated in this section or equivalent. To comply with the EN Standard or UL/C-
UL (CSA) Standard, use the products which conform to the corresponding standard.

12.2.1 Recommended wires

(1) Wires for power supply wiring

The following diagram shows the wires used for wiring. Use the wires given in this section or equivalent.

C

P

U

V

W

L

11

L

21

B1

B2

U

V

W

L

1

L

2

L

3

Motor

N

1) Main circuit power supply lead

Power supply

3) Motor power supply lead

Electro-
magnetic
brake

Encoder

5) Electromagnetic
brake lead

2) Control power supply lead

Cooling fan

BU

BV

BW

Cooling fan lead

Power supply

Regenerative option

4) Regenerative option lead

Encoder cable
(refer to section 12.1.4)

Servo motor

Servo amplifier

4) Power regeneration
converter lead

Power regeneration
converter

The following table lists wire sizes. The wires used assume that they are 600V vinyl wires and the
wiring distance is 30m(98.4ft) max. If the wiring distance is over 30m(98.4ft), choose the wire size in
consideration of voltage drop.
The alphabets (a, b, c) in the table correspond to the crimping terminals (Table 12.2) used to wire the
servo amplifier. For connection with the terminal block TE2 of the MR-J2S-100B or less, refer to
section 3.9.
The servo motor side connection method depends on the type and capacity of the servo motor. Refer to
section 3.6.
To comply with the UL/C-UL (CSA) Standard, use UL-recognized copper wires rated at 60 (140 ) or
more for wiring.

Advertising