Operation and display – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 88

Advertising
background image

4 - 7

4. OPERATION AND DISPLAY

(c) Program operation

Positioning operation can be performed in two or more operation patterns combined, without using
the servo system controller. Use this operation with the forced stop reset. This operation may be
used independently of whether the servo is on or off and whether the servo system controller is
connected or not.
Exercise control on the programmed operation screen of the MR Configurator (servo configuration
software). For full information, refer to the MR Configurator (Servo Configuration Software)
Installation Guide.

Operation

Screen Control

Start

Click the "Start" button.

Stop

Click the "Reset" button.

(d) Motorless operation

POINT

Motor-less operation may be used with the MR Configurator (servo
configuration software). Usually, however, use motor-less operation which
is available by making the servo system controller parameter setting.

Without connecting the servo motor, output signals or status displays can be provided in response
to the servo system controller commands as if the servo motor is actually running. This operation
may be used to check the servo system controller sequence. Use this operation with the forced stop
reset. Use this operation with the servo amplifier connected to the servo system controller.
Exercise control on the motor-less operation screen of the MR Configurator (servo configuration
software).

1) Load conditions

Load Item

Condition

Load torque

0

Load inertia moment ratio

Same as servo motor inertia moment

2) Alarms

The following alarms and warning do not occur. However, the other alarms and warnings occur
as when the servo motor is connected.

Encoder error 1 (16)
Encoder error 2 (20)
Absolute position erasure (25)
Battery cable breakage warning (92)
Battery warning (9F)

(e) Output signal (DO) forced output

Output signals can be switched on/off forcibly independently of the servo status. Use this function
for output signal wiring check, etc.
Exercise control on the DO forced output screen of the MR Configurator (servo configuration
software).