Troubleshooting – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 139

Advertising
background image

9 - 6

9. TROUBLESHOOTING

Display

Name

Definition

Cause

Action

1. Ambient temperature of servo

motor is over 40 (104 ).

Review environment so that ambient
temperature is 0 to 40 (32 to 104 ).

2. Servo motor is overloaded.

1. Reduce load.
2. Review operation pattern.
3. Use servo motor that provides larger

output.

46

Servo motor
overheat

Servo motor
temperature rise
actuated the
thermal sensor.

3. Thermal sensor in encoder is

faulty.

Change the servo motor.

1. Servo amplifier is used in excess

of its continuous output current.

1. Reduce load.
2. Review operation pattern.
3. Use servo motor that provides larger

output.

2. Servo system is instable and

hunting.

1. Repeat acceleration/

deceleration to execute auto tuning.

2. Change the auto tuning response

setting.

3. Set auto tuning to OFF and make gain

adjustment manually.

3. Machine struck something.

1. Review operation pattern.
2. Install limit switches.

4. Wrong connection of servo motor.

Servo amplifier's output terminals
U, V, W do not match servo
motor's input terminals U, V, W.

Connect correctly.

50

Overload 1

Load exceeded
overload protection
characteristic of
servo amplifier.

5. Encoder faulty.

Checking method

When the servo motor shaft is
rotated with the servo off,the
cumulative feedback pulses do
not vary in proportion to the
rotary angle of the shaft but the
indication skips or returns midway.

Change the servo motor.

1. Machine struck something.

1. Review operation pattern.
2. Install limit switches.

2. Wrong connection of servo motor.

Servo amplifier's output terminals
U, V, W do not match servo
motor's input terminals U, V, W.

Connect correctly.

3. Servo system is instable and

hunting.

1. Repeat acceleration/deceleration to

execute auto tuning.

2. Change the auto tuning response

setting.

3. Set auto tuning to OFF and make gain

adjustment manually.

51

Overload 2

Machine collision or
the like caused max.
For the time of the
alarm occurrence,
refer to the section
11.1.

4. Encoder faulty.

Checking method

When the servo motor shaft is
rotated with the servo off,the
cumulative feedback pulses do
not vary in proportion to the
rotary angle of the shaft but the
indication skips or returns midway.

Change the servo motor.

Advertising