Parameters – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 102

Advertising
background image

5 - 13

5. PARAMETERS

Classifi-

cation

No. Symbol

Name and Function

Initial

Value

Unit

Setting

Range

60

*OPC

Optional function C
Used to select the encoder pulse output direction.

CW

CCW

Encoder pulse output phase changing
Changes the phases of A, B-phase encoder pulses
output .

A-phase

B-phase

Servo motor rotation direction

Set value

0

1

A-phase

B-phase

A-phase

B-phase

A-phase

B-phase

0

0

0

0000

Refer to

Name

and

function

column.

E

xpa

n

si

on

pa

ra

m

et

er 2

61

NH2

Machine resonance suppression filter 2
Used to selection the machine resonance suppression filter 2. (Refer
to section 7.2.)

Notch frequency selection
Set "00" when you have set adaptive vibration
suppression control to be "valid" or "held"
(parameter No. 25: 1 or 2 ).

173.1
166.7
160.1
155.2

145.2

187.5

00

4500
2250

08
09

0A

2
3

0

0

1

0B
0C

0D
0E

0F

10
11
12
13
14
15
16
17

18
19

1A
1B
1C
1D

1E
1F

1500
1125

900
750

642.9

500
450

409.1

375

346.2
321.4

300

562.5

281.3
264.7

250

236.8

225

214.3
204.5
195.7

180

150

01
02
03
04
05
06
07

40dB

14dB

8dB

4dB

Setting Frequency

Invalid

Notch depth selection

Depth

Gain

Deep

Shallow

to

Setting

Setting

Setting

Setting

Frequency

Frequency

Frequency

0000

Refer to

Name

and

function

column.

Advertising