12. OPTIONS AND AUXILIARY EQUIPMENT

MR-JHSCBL2M-L
MR-JHSCBL5M-L

MR-JHSCBL2M-H
MR-JHSCBL5M-H

MR-ENCBL2M-H
MR-ENCBL5M-H

MR-JHSCBL10M-L

to

MR-JHSCBL30M-L

MR-JHSCBL10M-H

to

MR-JHSCBL50M-H

MR-ENCBL10M-H

to

MR-ENCBL50M-H

Servo amplifier side

Encoder side

Servo amplifier side

Encoder side Servo amplifier side

Encoder side

Use of AWG22

(10m(32.8ft) to 50m(164.0ft))

Use of AWG24

(10m(32.8ft) to 50m(164.0ft))

(Note 1)

Plate

Plate

P5
LG
P5
LG
MR
MRR
P5
LG
BAT
LG

SD

19
11
20
12

7

17
18

2
9
1

Plate

S

R

F
G

N

C
D

P5
LG
P5
LG
P5
LG

MR

MRR

BAT
LG

SD

19
11
20
12
18

2

7

17

9
1

S

R
C
D

F

N

G

P5
LG
P5
LG
P5
LG

MR
MRR

BAT
LG

SD

19
11
20
12
18

2

7

17

9
1

S

R
C
D

F

N

G

(Note 1)

(Note@2) Use of AWG24

(Less than 10m(32.8ft))

(Note 1)

Note 1. This wiring is required for use in the absolute position detection system. This wiring is not needed for use in the incremental

system.

2. AWG28 can be used for 5m(16.4ft) or less.

When fabricating an encoder cable, use the recommended wires given in section 12.2.1 and the
MR-J2CNS connector set for encoder cable fabrication, and fabricate an encoder cable in
accordance with the optional encoder cable wiring diagram given in this section. You can
fabricate an encoder cable of up to 50m(164.0ft) length.
Refer to chapter 3 of the servo motor instruction guide and choose the encode side connector
according to the servo motor installation environment.