Parameters – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 91

Advertising
background image

5 - 2

5. PARAMETERS

(1) Item list

Classifi-

cation

No. Symbol

Name

(Note 1)

Initial

Value

Unit

Customer

setting

1

*AMS

Amplifier setting

0000

2

*REG

Regenerative resistor

0000

3

0080

4

000

5

For manufacturer setting by servo system controller
Automatically set from the servo system controller

1

6

*FBP

Feedback pulse number

0

7

*POL

Rotation direction selection

0

8

ATU

Auto tuning

0001

9

RSP

Servo response

7kW or

less: 0005

11kW or

more: 0002

10

TLP

Forward rotation torque limit (Note 2)

300

%

B

asi

c pa

ra

m

et

ers

11

TLN

Reverse rotation torque limit (Note 2)

300

%

12

GD2

Ratio of load inertia to servo motor inertia (load inertia ratio)

7.0

times

13

PG1

Position control gain 1

7kW or

less: 35

11kW or

more: 19

rad/s

14

VG1

Speed control gain 1

7kW or

less: 177

11kW or

more: 96

rad/s

15

PG2

Position control gain 2

7kW or

less: 35

11kW or

more: 19

rad/s

16

VG2

Speed control gain 2

7kW or

less: 817

11kW or

more:

455

rad/s

17

VIC

Speed integral compensation

7kW or

less:48

11kW or

more:91

ms

18

NCH

Machine resonance suppression filter 1 (Notch filter)

0000

19

FFC

Feed forward gain

0

%

20

INP

In-position range

100

pulse

21

MBR

Electromagnetic brake sequence output

0

ms

22

MOD

Analog monitor output

0001

23

*OP1

Optional function 1

0000

24

*OP2

Optional function 2

0000

25

LPF

Low-pass filter/adaptive vibration suppression control

0000

Ad

ju

st

me

n

t p

ar

ame

te

rs

26

For manufacturer setting

0

27

MO1

Analog monitor 1 offset

0

mV

28

MO2

Analog monitor 2 offset

0

mV

29

For manufacturer setting

0001

30

ZSP

Zero speed

50

r/min

31

ERZ

Error excessive alarm level

80

(Note 3)

0.025rev

32

OP5

Optional function 5

0000

33

*OP6

Optional function 6

0000

34

VPI

PI-PID control switch-over position droop

0

pulse

35

For manufacturer setting

0

36

VDC

Speed differential compensation

980

37

For manufacturer setting

0010

38

*ENR

Encoder pulses output

4000

pulse/rev

39

For manufacturer setting

0

E

xpa

n

si

on

pa

ra

m

et

ers

40

*BLK

Parameter write inhibit (Note 2)

0000

Note 1. Factory settings of the servo amplifier. Connecting it with the servo system controller and switching power on changes them to

the settings of the servo system controller.

2. Setting and changing cannot be made from the peripheral software of the motion controller.
3. The setting unit of 0.025rev applies for the servo amplifier of software version B1 or later. For the amplifier of software version

older than B1, the setting unit of 0.1rev is applied.