Options and auxiliary equipment, 2) connection example – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 177

Advertising
background image

12 - 18

12. OPTIONS AND AUXILIARY EQUIPMENT

(2) Connection example

NFB

MC

Servo amplifier

L

11

L

21

L

1

L

2

L

3

EM1

SG

Power regeneration
converter FR-RC

SK

ON

MC

B C

RDY

SE

Alarm
output

RDY
output

A

B

C

5m(16.4ft) or less

Operation ready

MC

OFF

EM1

RA2

FR-RC

Ready

COM

VDD

R/L

1

S/L

2

T/L

3

B

C

RX

R

SX

S

TX

T

N

P

C

P

1

N/

P/

(Note 5)
Power
supply

(Note 3) Power factor improving reactor

FR-BAL

(Note 1)
Phase detection
terminals

(Note 4)

(Note 2)

Note 1. When not using the phase detection terminals, fit the jumpers across RX-R, SX-S and TX-T. If the jumpers remain removed, the

FR-RC will not operate.

2. When using servo amplifiers of 5kW and 7kW, always remove the lead of built-in regenerative resistor connected to P terminal

and C terminal.

3. For the power factor improving reactor (FR-BAL) to be used, refer to POWER REGENERATION CONVERTER FR-RC

INSTRUCTION MANUAL (IB (NA) 67096). When using FR-BAL with the servo amplifier of 11 k to 22 kW, do not use with the
power factor improving reactor (FR-BAL).

4. When using the servo amplifier of 11k to 22kW, make sure to connect P

1

and P. (Factory-wired.)

5. Refer to section 1.3 for the power supply specification.