9. TROUBLESHOOTING

Display

Name

Definition

Cause

Action

1. Faulty parts in the servo amplifier

Checking method

Alarm (15) occurs if power is
switched on after disconnection
of all cables but the control
circuit power supply cables.

15

Memory error 2 EEP-ROM fault

2. The number of write times to EEP-

ROM exceeded 100,000.

Change the servo amplifier.

1. Encoder connector (CN2)

disconnected.

Connect correctly.

2. Encoder fault

Change the servo motor.

16

Encoder error 1 Communication

error occurred
between encoder
and servo amplifier. 3. Encoder cable faulty

(Wire breakage or shorted)

Repair or change the cable.

CPU/parts fault

1. Faulty parts in the servo amplifier

Checking method

Alarm (17) occurs if power is
switched on after disconnection
of all cable but the control circuit
power supply cable.

Change the servo amplifier.

17

Board error

The output

terminals U, V, W of

the servo amplifier

and the input

terminals U, V, W of

the servo motor are

not connected.

2. The wiring of U, V, W is

disconnected or not connected.

Correctly connect the output terminals U,

V, W of the servo amplifier and the input

terminals U, V, W of the servo motor.

19

Memory error 3 ROM memory fault Faulty parts in the servo amplifier

Checking method

Alarm (19) occurs if power is
switched on after disconnection
of all cable but the control circuit
power supply cable.

Change the servo amplifier.

1A

Motor

combination

error

Wrong combination

of servo amplifier

and servo motor.

Wrong combination of servo

amplifier and servo motor connected.

Use correct combination.

1. Encoder connector (CN2)

disconnected.

Connect correctly.

2. Encoder fault

Change the servo motor.

Communication

error occurred

between encoder

and servo amplifier. 3. Encoder cable faulty

(Wire breakage or shorted)

Repair or change the cable.

20

Encoder error 2

Encoder detected

acceleration error.

4. Excessive acceleration is occurred

due to oscillation and others.

1. Decrease the speed control gain 2.

2. Decrease the auto tuning response level.

1. Power input wires and servo motor

output wires are in contact at

main circuit terminal block (TE1).

Connect correctly.

2. Sheathes of servo motor power

cables deteriorated, resulting in

ground fault.

Change the cable.

24

Main circuit

error

Ground fault

occurred at the

servo motor outputs

(U,V and W phases)

of the servo

amplifier.

3. Main circuit of servo amplifier

failed.

Checking method

Alarm (24) occurs if the servo is
switched on after disconnecting
the U, V, W power cables from
the servo amplifier.

Change the servo amplifier.

1. Battery voltage low

Absolute position

data in error

2. Battery cable or battery is faulty.

Change the battery.

Always make home position setting again.

25

Absolute

position erase

Power was switched

on for the first time

in the absolute

position detection

system.

3. Super capacitor of the absolute

position encoder is not charged.

After leaving the alarm occurring for a few

minutes, switch power off, then on again.

Always make home position setting again.