4. OPERATION AND DISPLAY

4.3 Servo amplifier display

On the servo amplifier display (two-digit, seven-segment display), check the status of communication with
the servo system controller at power-on, check the axis number, and diagnose a fault at occurrence of an
alarm.
(1) Display sequence

Servo amplifier power ON

Waiting for servo system controller
power to switch ON

Servo system controller power ON

When alarm occurs,
alarm code appears.

Ready ON

Ready OFF/servo OFF

Ready ON/servo OFF

Servo ON

Ordinary operation

Servo system controller power OFF

Ready ON/servo ON

(Note)

(Note)

(Note)

Servo system controller power ON

During forced stop and forced stop

Forced stop and forced stop
reset

or

Note. The right-hand segments of b1, c1 and d1
indicate the axis number.
(Axis 1 in this example)

Initial data communication