12. OPTIONS AND AUXILIARY EQUIPMENT

For the MR-RB50 MR-RB51 install the cooling fan as shown.

82.5

40 (1.58)

82.5

13

3

Cooling fan installation screw hole dimensions

2-M3 screw hole
(for cooling fan installation)
Depth 10 or less
(Screw hole already

machined)

Cooling fan

Terminal block

Thermal relay

Installation surface

Horizontal installation

Vertical

installation

Top

Bottom

(3

.2

5

)

(5.

24)

(3.25)

[Unit : mm(in)]

(c) MR-J2S-11KB to MR-J2S-22KB (when using the supplied regenerative resistor)

When using the regenerative resistors supplied to the servo amplifier, the specified number of
resistors (4 or 5 resistors) must be connected in series. If they are connected in parallel or in less
than the specified number, the servo amplifier may become faulty and/or the regenerative resistors
burn. Install the resistors at intervals of about 70mm. Cooling the resistors with two cooling fans
(92 92, minimum air flow : 1.0m

3

) improves the regeneration capability. In this case, set "0E "

in parameter No. 2.

P
C

Cooling fan

5m or less

Do not remove
the short bar.

Servo amplifier

P

1

(Note) Series connection

Note. The number of resistors connected in series depends on the resistor type. Install a thermal sensor or like to configure a circuit that

will shut off the main circuit power at abnormal overheat. The supplied regenerative resistor does not have a built-in thermal
sensor. If the regenerative brake circuit fails, abnormal overheat of the resistor is expected to occur. On the customer side, please
also install a thermal sensor for the resistor and provide a protective circuit that will shut off the main circuit power supply at
abnormal overheat. The detection level of the thermal sensor changes depending on the resistor installation method. Please
install the thermal sensor in the optimum position according to the customer's design standards, or use our regenerative option
having built-in thermal sensor (MR-RB65, 66, 67).

Regenerative power [W]

Servo amplifier

Regenerative

resistor

Normal

Cooling

Resistance

[ ]

Number of

resistors

MR-J2S-11KB

GRZG400-2

500

800

8

4

MR-J2S-15KB

GRZG400-1

850

1300

5

5

MR-J2S-22KB GRZG400-0.8

850

1300

4

5