Parameters – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 98

Advertising
background image

5 - 9

5. PARAMETERS

Classifi-

cation

No. Symbol

Name and Function

Initial

Value

Unit

Setting

Range

24

*OP2

Optional function 2
Used to select slight vibration suppression control and motor-less
operation

0

0

Slight vibration suppression control selection
Made valid when auto tuning selection is
set to "0002" in parameter No.8.
Used to suppress vibration at a stop.
0: Invalid
1: Valid

Motor-less operation selection
0: Invalid
1: Makes motor-less operation valid.
When motor-less operation is made valid, signal output or
status display can be provided as if the servo motor is
running actually in response to the servo system controller
command, without the servo motor being connected.
Motor-less operation is performed as in the motor-less
operation using the MR Configurator (servo configuration
software). (Refer to (d), (1) of section 4.4.)

0000

Refer to
name
and
function
column.

25

LPF

Low-pass filter/adaptive vibration suppression control
Used to select the low-pass filter and adaptive vibration suppression
control. (Refer to chapter 7.)

Low-pass filter selection
0: Valid (Automatic adjustment)
1: Invalid
When you choose "valid", the filter of the handwidth
represented by the following expression is set
automatically.

0

0: Invalid
1: Valid
Machine resonance frequency is always detected
and the filter is generated in response to resonance to
suppress machine vibration.
2: Held
The characteristics of the filter generated so far are
held, and detection of machine resonance is stopped.

Adaptive vibration suppression control selection

Adaptive vibration suppression control sensitivity
selection
Used to select the sensitivity of machine resonance
detection.
0: Normal
1: Large sensitivity

2 (1 GD2 setting 0.1)

VG2 setting 10

For 1kW or less

2 (1 GD2 setting 0.1)

VG2 setting 5

For 2kW or more

[H

z

]

[H

z

]

0000

Refer to
name
and
function
column.

Ad

ju

st

me

n

t p

ar

ame

te

rs

26

For manufacturer setting
Do not change this value by any means.

0