5 - 6

5. PARAMETERS

Classifi-

cation

No. Symbol

Name and Function

Initial

Value

Unit

Setting

Range

9

RSP

Servo response
Used to select the response of auto tuning.

Response level selection

If the machine hunts or generates large gear
sound, decrease the set value.
To improve performance, e.g. shorten the
settling time, increase the set value.

Set

value

Response

level

1

Low

response

Middle

response

High

response

Machine resonance
frequency guideline

15Hz

2

20Hz

3

25Hz

4

30Hz

5

35Hz

6

45Hz

7

55Hz

8

70Hz

9

85Hz

A

105Hz

B

130Hz

C

160Hz

D

200Hz

E

240Hz

F

300Hz

0

0

0

7kW or

less

:0005

11kW or

more

:0002

Refer to
name
and
function
column.

10

TLP

Forward rotation torque limit
Assume that the rated torque is 100[%].
Used to limit the torque in the forward rotation driving mode and
reverse rotation regenerative mode.
In other than the test operation mode on the MR Configurator (servo
configuration software), the torque limit value on the servo system
controller side is made valid.

300

%

0

to

500

B

asi

c pa

ra

m

et

ers

11

TLN

Reverse rotation torque limit
Assume that the rated torque is 100[%].
Used to limit the torque in the forward rotation driving mode and
forward rotation regenerative mode.
In other than the test operation mode on the MR Configurator (servo
configuration software), the torque limit value on the servo system
controller side is made valid.

300

%

0

to

500

12

GD2

Ratio of load inertia to servo motor inertia (load inertia ratio)
Used to set the ratio of the load inertia (inertia moment) to the
inertia moment of the servo motor shaft. When auto tuning mode 1
and interpolation mode is selected, the result of auto tuning is
automatically used. (Refer to section 6.1.1)

7.0

times

0.0

to

300.0

Ad

ju

st

me

n

t p

ar

ame

te

rs

13

PG1

Position control gain 1
Used to set the gain of position loop 1. Increase the gain to improve
track ability performance in response to the position command.
When auto turning mode 1,2 is selected, the result of auto turning is
automatically used.

7kW or

less:35

11kW or

more:19

rad/s

4

to

2000

Advertising