12 - 7

12. OPTIONS AND AUXILIARY EQUIPMENT

(d) MR-J2S-11KB-PX to MR-J2S-22KB-PX (when using the regenerative option)

The MR-J2S-11KB-PX to MR-J2S-22KB-PX servo amplifiers are not supplied with regenerative
resistors. When using any of these servo amplifiers, always use the MR-RB65, 66 or 67
regenerative option.
The MR-RB65, 66 and 67 are regenerative options that have encased the GRZG400-2

Ω

, GRZG400-

1

Ω

and GRZG400-0.8

Ω

, respectively. When using any of these regenerative options, make the

same parameter setting as when using the GRZG400-2

Ω

, GRZG400-1

Ω

or GRZG400-0.8

Ω

(supplied regenerative resistors or regenerative option is used with 11kW or more servo amplifier).
Cooling the regenerative option with cooling fans improves regenerative capability.
The G3 and G4 terminals are for the thermal sensor. G3-G4 is opened when the regenerative
option overheats abnormally.

G3

G4

C

P

C

P

P

1

Regenerative option

Do not remove
the short bar.

Configure up a circuit which
shuts off main circuit power
when thermal sensor operates.

Servo amplifier

(Note)

Note. Specifications of contact across G3-G4

Maximum voltage :120V AC/DC
Maximum current :0.5A/4.8VDC
Maximum capacity : 2.4VA

Regenerative power [W]

Servo amplifier

Regenerative

option model

Resistance

[ ]

Without

cooling fans

With

cooling fans

MR-J2S-11KB-PX

MR-RB65

8

500

800

MR-J2S-15KB-PX

MR-RB66

5

850

1300

MR-J2S-22KB-PX

MR-RB67

4

850

1300

When using cooling fans, install them using the mounting holes provided in the bottom of the
regenerative option. In this case, set "0E " in parameter No. 2.

Top

Bottom

TE1

G4 G3 C P

TE

2 cooling fans
(92 92, minimum air flow: 1.0m

3

)

MR-RB65 66 67

Mounting screw