4 external dynamic brake, Options and auxiliary equipment – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 179

Advertising
background image

12 - 20

12. OPTIONS AND AUXILIARY EQUIPMENT

12.1.4 External dynamic brake

POINT

Configure up a sequence which switches off the contact of the brake unit
after (or as soon as) it has turned off the servo on signal at a power failure
or failure.
For the braking time taken when the dynamic brake is operated, refer to
section 13.3.
The brake unit is rated for a short duration. Do not use it for high duty.

(1) Selection of dynamic brake

The dynamic brake is designed to bring the servo motor to a sudden stop when a power failure occurs
or the protective circuit is activated, and is built in the 7kW or less servo amplifier. Since it is not built
in the 11kW or more servo amplifier, purchase it separately if required. Set " 1

" in the parameter

No. 2.

Servo amplifier

Dynamic brake

MR-J2S-11KB

DBU-11K

MR-J2S-15KB

DBU-15K

MR-J2S-22KB

DBU-22K

Advertising