7 servo motor with electromagnetic brake, Signals and wiring, Caution – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 65

Advertising
background image

3 - 22

3. SIGNALS AND WIRING

3.7 Servo motor with electromagnetic brake

CAUTION

Configure the electromagnetic brake circuit so that it is activated not only by the

interface unit signals but also by a forced stop (EM1).

EM1

RA

24VDC

Contacts must be open when
servo-off, when an alarm occurrence
and when an electromagnetic brake
interlock (MBR).

Electromagnetic brake

Servo motor

Circuit must be
opened during
forced stop (EM1).

The electromagnetic brake is provided for holding purpose and must not be used

for ordinary braking.

Before performing the operation, be sure to confirm that the electromagnetic brake

operates properly.

POINT

Refer to the Servo Motor Instruction Manual for specifications such as the
power supply capacity and operation delay time of the electromagnetic
brake.

Note the following when the servo motor equipped with electromagnetic brake is used.

1) Do not share the 24VDC interface power supply between the interface and electromagnetic

brake. Always use the power supply designed exclusively for the electromagnetic brake.

2) The brake will operate when the power (24VDC) switches off.

3) Switch off the servo-on command after the servo motor has stopped.

(1) Connection diagram

MBR

COM

Servo amplifier

Servo motor

B1

B2

Forced

stop

RA

24VDC

RA

VDD

(2) Setting

In parameter No.21 (electromagnetic brake sequence output), set the time delay (Tb) from
electromagnetic brake operation to base circuit shut-off at a servo off time as in the timing chart in (3)