Functions and configuration – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 35

Advertising
background image

1 - 18

1. FUNCTIONS AND CONFIGURATION

(b) For 1-phase 100V to 120V

L

1

L

2

L

21

L

11

U

V

W

D

P

C

No-fuse breaker
(NFB) or fuse

Magnetic
contactor
(MC)

To CN2

To CN3

To CN1B

To CN1A

Servo motor

Personal
computer

MR Configurator
(Servo configuration
software
MRZJW3-SETUP151E)

Servo amplifier

CHARGE

Control circuit terminal block

Options and auxiliary equipment

No-fuse breaker

Magnetic contactor

MR Configurator
(Servo configuration software)

Regenerative option

Reference

Section 12.2.2

Section 12.2.2

Section 12.1.8

Section 12.1.1

Options and auxiliary equipment

Reference

Cables

Section 12.2.1

Servo system

controller

or

preceding axis
servo amplifier

CN1B

Subsequent axis

servo amplifier

CN1A

or

Termination

connector

Power factor improving reactor Section 12.2.3

Power
factor
improving
reactor
(FR-BAL)

(Note 1)
Encoder cable

(Note 1)
Power supply lead

(Note 2)
Power supply

Regenerative option

Note 1. The HC-SFS, HC-RFS series have cannon connectors.
2. Refer to section 1.3 for the power supply specification.