Options and auxiliary equipment, Caution – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 191

Advertising
background image

12 - 32

12. OPTIONS AND AUXILIARY EQUIPMENT

(4) Bus cable

CAUTION

When fabricating the bus cable, do not make incorrect connection. Doing so can

cause misoperation or explosion.

When fabricating this cable, use the recommended cable given in section 12.2.1 and fabricate it in
accordance with the connection diagram shown in this section. The overall distance of the bus cable on
the same bus is 30m(98.4ft).

(a) MR-J2HBUS M-A

1) Model definition

Model: MR-J2HBUS M-A

05

Cable length [m(ft)]

5

Symbol

0.5 (1.64)

5 (16.4)

1 (3.28)

1

2) Connection diagram

MR-J2HBUS M-A

SD

LG

LG

RD

RD*

TD

TD*

LG

LG

EMG*

EMG

1

11

2

12

4

14

5

15

6

16

20

Plate

1

11

2

12

4

14

5

15

7

17

PCR-S20FS (Connector)
PCR-LS20LA1(Case)

10120-6000EL(Connector)
10320-3210-000(Shell kit)