13. ABSOLUTE POSITION DETECTION SYSTEM

13.2 Specifications

(1) Specification list

Item

Description

System

Electronic battery backup system

Battery

1 piece of lithium battery ( primary battery, nominal 3.6V)
Type: MR-BAT or A6BAT

Maximum revolution range

Home position 32767 rev.

(Note 1)

Maximum speed at power failure

500r/min

(Note 2)

Battery backup time

Approx. 10,000 hours (battery life with power off)

(Note 3)

Data holding time during battery

replacement

2 hours at delivery, 1 hour in 5 years after delivery

Battery storage period

5 years from date of manufacture

Note 1. Maximum speed available when the shaft is rotated by external force at the time of power failure or the like.
2. Time to hold data by a battery with power off. It is recommended to replace the battery in three years independently of

whether power is kept on or off.

3. Period during which data can be held by the super capacitor in the encoder after power-off, with the battery voltage low or

the battery removed, or during which data can be held with the encoder cable disconnected.
Battery replacement should be finished within this period.

(2) Configuration

CN1

CN2

CN5

Servo system controller

Servo amplifier

Battery (MR-BAT)

Servo motor

(3) Parameter setting

Set "0001" in parameter No.1 to make the absolute position detection system valid.

Absolute position detection selection
0: Used in incremental system.
1: Used in absolute position
detection system.