Parameters – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 96

Advertising
background image

5 - 7

5. PARAMETERS

Classifi-

cation

No. Symbol

Name and Function

Initial

Value

Unit

Setting

Range

14

VG1

Speed control gain 1
Normally this parameter setting need not be changed. Higher setting
increases the response level but is liable to generate vibration and/or
noise.
When auto tuning mode 1,2 and interpolation mode is selected, the
result of auto tuning is automatically used.

7kW or

less:177

11kW or

more:96

rad/s

20

to

5000

15

PG2

Position control gain 2
Used to set the gain of the position loop.
Set this parameter to increase position response to load disturbance.
Higher setting increases the response level but is liable to generate
vibration and/or noise.
When auto tuning mode 1 2, manual mode and interpolation mode
is selected, the result of auto tuning is automatically used.

7kW or

less:35

11kW or

more:19

rad/s

1

to

1000

16

VG2

Speed control gain 2
Set this parameter when vibration occurs on machines of low
rigidity or large backlash.
Higher setting increases the response level but is liable to generate
vibration and/or noise.
When auto tuning mode 1 2 and interpolation mode is selected, the
result of auto tuning is automatically used.

7kW or

less:817

11kW or

more:455

rad/s

20

to

20000

17

VIC

Speed integral compensation
Used to set the constant of integral compensation.
When auto tuning mode 1 2 and interpolation mode is selected, the
result of auto tuning is automatically used.

7kW or

less:48

11kW or

more:91

ms

1

to

1000

18

NCH

Machine resonance suppression filter 1 (Notch filter)
Used to select the machine resonance suppression filter.
(Refer to section 7.2.)

2
3

0

0

1

Notch frequency selection

00
01
02
03
04
05
06
07

Setting Frequency

Invalid

4500
2250
1500
1125
900
750
642.9

08
09
0A
0B
0C
0D
0E
0F

Setting

562.5
500
450
409.1
375
346.2
321.4
300

Frequency

10
11
12
13
14
15
16
17

Setting

281.3
264.7
250
236.8
225
214.3
204.5
195.7

Frequency

18
19
1A
1B
1C
1D
1E
1F

Setting

187.5
180
173.1
166.7
160.1
155.2
150
145.2

Frequency

Notch depth selection

Setting

Depth

Gain

Deep

Shallow

to

4dB

40dB
14dB

8dB

0000

Refer to
name
and
function
column.

Ad

ju

st

me

n

t p

ar

ame

te

rs

19

FFC

Feed forward gain
Set the feed forward gain. When the setting is 100%, the droop
pulses during operation at constant speed are nearly zero. However,
sudden acceleration/deceleration will increase the overshoot. As a
guideline, when the feed forward gain setting is 100%, set 1s or more
as the acceleration/deceleration time constant up to the rated speed.

0

%

0

to

100

Advertising