3 parameters, Special adjustment functions – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 127

Advertising
background image

7 - 6

7. SPECIAL ADJUSTMENT FUNCTIONS

7.5.3 Parameters

When using the gain changing function, always set " 2 " in parameter No.8 (auto tuning) to choose
the manual mode 2 of the gain adjustment modes. The gain changing function cannot be used in the auto
tuning mode.

Parameter

No.

Abbrevi

ation

Name

Unit

Description

13

PG1

Position control gain 1

rad/s

14

VG1

Speed control gain 1

rad/s

Position and speed gains of a model used to set the response
level to a command. Always valid.

12

GD2

Ratio of load inertia moment to
servo motor inertia moment

0.1

times

15

PG2

Position control gain 2

rad/s

16

VG2

Speed control gain 2

rad/s

17

VIC

Speed integral compensation

ms

Control parameters before changing

52

GD2B

Ratio of load inertia moment to
servo motor inertia moment 2

0.1

times

Used to set the ratio of load inertia moment to servo motor
inertia moment after changing.

53

PG2B

Position control gain 2 changing
ratio

%

Used to set the ratio (%) of the after-changing position
control gain 2 to position control gain 2.

54

VG2B

Speed control gain 2 changing
ratio

%

Used to set the ratio (%) of the after-changing speed control
gain 2 to speed control gain 2.

55

VICB

Speed integral compensation
changing ratio

%

Used to set the ratio (%) of the after-changing speed integral
compensation to speed integral compensation.

49

CDP

Gain changing selection

Used to select the changing condition.

50

CDS

Gain changing condition

kpps

pulse
r/min

Used to set the changing condition values.

51

CDT

Gain changing time constant

ms

You can set the filter time constant for a gain change at
changing.

Advertising