2 the dynamic brake at the load inertia moment, 4 encoder cable flexing life, Characteristics – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 158

Advertising
background image

11 - 7

11. CHARACTERISTICS

11.3.2 The dynamic brake at the load inertia moment

Use the dynamic brake under the load inertia moment ratio indicated in the following table. If the load
inertia moment is higher than this value, the built-in dynamic brake may burn. If there is a possibility
that the load inertia moment may exceed the value, contact Mitsubishi.

Servo amplifier

Load inertia moment ratio [times]

MR-J2S-10B to MR-J2S-200B

MR-J2S-10B1 to MR-J2S-40B1

30

MR-J2S-350B

16

MR-J2S-500B
MR-J2S-700B

15

(Note)

MR-J2S-11KB to MR-J2S-22KB

(Note)

30

Note. Assumes that the external dynamic brake is used.

11.4 Encoder cable flexing life

The flexing life of the cables is shown below. This graph calculated values. Since they are not guaranteed
values, provide a little allowance for these values.

1 10

7

5 10

7

1 10

8

5 10

6

1 10

6

5 10

5

1 10

5

5 10

4

1 10

4

5 10

3

1 10

3

a

b

F

le

xi

ng

li

fe

[t

im

es

]

4

7

10

20

40

70 100

200

Flexing radius [mm]

a : Long flexing-life encoder cable
MR-JCCBL M-H
MR-JHSCBL M-H
MR-ENCBL M-H

b : Standard encoder cable
MR-JCCBL M-L
MR-JHSCBL M-L

Advertising