2 fr-bu2 brake unit, Options and auxiliary equipment – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 169

Advertising
background image

12 - 10

12. OPTIONS AND AUXILIARY EQUIPMENT

12.1.2 FR-BU2 brake unit

POINT

The brake unit and resistor unit of other than 200V class are not
applicable to the servo amplifier. Combination of different voltage class
units and servo amplifier cannot be used.
Install a brake unit and a resistor unit on a flat surface vertically. When
the unit is installed horizontally or diagonally, the heat dissipation effect
diminishes.
Temperature of the resistor unit case rises to higher than 100 . Keep
cables and flammable materials away from the case.
Ambient temperature condition of the brake unit is between 10 (14 )
and 50 (122 ). Note that the condition is different from the ambient
temperature condition of the servo amplifier (between 0 (32 ) and

55 (131 )).

Configure the circuit to shut down the power-supply with the alarm
output of the brake unit and resistor unit under abnormal condition.
Use the brake unit with a combination indicated in (1) of this section.
For executing a continuous regenerative operation, use FR-RC power
regeneration converter or FR-CV power regeneration common converter.
Brake unit and regenerative options (Regenerative resistor) cannot be
used simultaneously.

Connect the brake unit to the bus of the servo amplifier. As compared to the MR-RB regenerative option,
the brake unit can return larger power. Use the brake unit when the regenerative option cannot provide
sufficient regenerative capability.
When using the brake unit, set the parameter No.2 of the servo amplifier to " 01".
When using the brake unit, always refer to the FR-BU2-(H) Brake Unit Instruction Manual.

(1) Selection

Use a combination of servo amplifier, brake unit and resistor unit listed below.

Brake unit

Resistor unit

Number of
connected

units

Permissible

continuous

power [kW]

Total

resistance

[ ]

Applicable servo

amplifier

FR-BU2-15K

FR-BR-15K

1

0.99

8

MR-J2S-350B
MR-J2S-500B

FR-BU2-30K

FR-BR-30K

1

1.99

4

MR-J2S-500B
MR-J2S-700B
MR-J2S-11KB
MR-J2S-15KB

FR-BU2-55K

FR-BR-55K

1

3.91

2

MR-J2S-11KB
MR-J2S-15KB
MR-J2S-22KB

MT-BR5-55K

1

5.5

2

MR-J2S-22KB

Advertising