12 - 36

12. OPTIONS AND AUXILIARY EQUIPMENT

12.1.6 Maintenance junction card (MR-J2CN3TM)

POINT

The MR-J2S-11KB or more allows only the relaying of signals using
CN3A/CN3C. Since TE1 cannot be used, keep it open.

(1) Usage

The maintenance junction card (MR-J2CN3TM) is designed for use when a personal computer and
analog monitor outputs are used at the same time.

CN3B

CN3C

CN3A

CN3

A1 A2 A3 A4 B4 B3 B2 B1 B5 B6 A5 A6

Communication cable

Maintenance junction card (MR-J2CN3TM)

Analog monitor 2

Analog monitor 1

Servo amplifier

Bus cable

MR-J2HBUS M

LG

MBR

VDD

COM

EM1

DI

MO1

EMGO

SG PE LG

MO2

Forced stop

Electromagnetic brake interlock

RA1

(2) Connection diagram

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

1

3

4

5

10

13

14

15

19

Shell

20

LG
LG
MO1
MO2

B5
B6
A5

A6

TE1

CN3A

VDD
COM

EM1
DI
MBR
EMGO
SG
PE

A1
A2
A3

A4

B4

B3

B2
B1

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

CN3B

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

CN3C

Shell

Shell

(3) Outline drawing

3(0.12)

41.5(1.63)

75

(2

.9

5)

88(3.47)

100(3.94)

M

R

-J

2C

N

3T

M

CN3A

CN3B

CN3C

A1

B1

A6

B6

TE1

[Unit: mm]
([Unit: in])

Mass: 110g(0.24Ib)

2- 5.3(0.21)(mounting hole)

Advertising