9 emc filter, Options and auxiliary equipment, 2) connection example – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 220

Advertising
background image

12 - 61

12. OPTIONS AND AUXILIARY EQUIPMENT

12.2.9 EMC filter

For compliance with the EMC directive of the EN standard, it is recommended to use the following filter.
Some EMC filters are large in leakage current.

(1) Combination with the servo amplifier

Recommended filter

Servo amplifier

Model

Leakage current [mA]

Mass

[kg]([Ib])

MR-J2S-10B to MR-J2S-100B

MR-J2S-10B1 to MR-J2S-40B1

SF1252

38

0.75(1.65)

MR-J2S-200B MR-J2S-350B

SF1253

57

1.37(3.02)

MR-J2S-500B

(Note)

HF3040A-TM

1.5

6.0(13.23)

MR-J2S-700B

(Note)

HF3050A-TM

1.5

6.7(14.77)

MR-J2S-11KB

(Note)

HF3060A-TMA

3.0

10.0(22.05)

MR-J2S-15KB

(Note)

HF3080A-TMA

3.0

13.0(28.66)

MR-J2S-22KB

(Note)

HF3100A-TMA

3.0

14.5(31.97)

Note. Soshin Electric. A surge protector is separately required to use any of these EMC filters. (Refer to the EMC Installation

Guidelines.)

(2) Connection example

L

1

L

2

L

3

L

11

L

21

L

1

L

2

L

3

L

1

L

2

L

3

LINE

LOAD

(Note 2)

NFB

MC

(Note 1)

Power

supply

EMC filter

(SF1252, SF1253)

Servo amplifier

L

1

L

2

L

3

L

11

L

21

Servo amplifier

1

2

3

4

5

6

E

MC

Surge protector 1
(RAV-781BYZ-2)
(OKAYA Electric Industries

Co., Ltd.)

Surge protector 2
(RAV-781BXZ-4)
(OKAYA Electric Industries Co., Ltd.)

NFB

(Note 1)

Power

supply

1

2

3

1 2 3

EMC filter

(SOSHIN Electric Co., Ltd)

Note 1. For 1-phase 230V power supply, connect the power supply to L

1

, L

2

and leave L

3

open. There is no L

3

for 1-phase 100 to 120V

power supply. Refer to section 1.3 for the power supply specification.

2. Connect when the power supply has earth.