4 function list, Functions and configuration – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 23

Advertising
background image

1 - 6

1. FUNCTIONS AND CONFIGURATION

1.4 Function list

The following table lists the functions of this servo. For details of the functions, refer to the reference field.

Function

Description

Reference

High-resolution encoder

High-resolution encoder of 131072 pulses/rev is used as a servo motor encoder.

Absolute position detection
system

Merely setting a home position once makes home position return unnecessary
at every power-on.

Chapter 13

Adaptive vibration
suppression control

Servo amplifier detects mechanical resonance and sets filter characteristics
automatically to suppress mechanical vibration.

Section 7.3

Low-pass filter

Suppresses high-frequency resonance which occurs as servo system response is
increased.

Section 7.4

Machine analyzer function

Analyzes the frequency characteristic of the mechanical system by simply
connecting a MR Configurator (servo configuration software)-installed personal
computer and servo amplifier.

Machine simulation

Can simulate machine motions on a personal computer screen on the basis of
the machine analyzer results. The MR Configurator (servo configuration
software) is required.

Gain search function

Personal computer changes gains automatically and searches for overshoot-
free gains in a short time. The MR Configurator (servo configuration software)
is required.

Slight vibration suppression
control

Suppresses vibration of 1 pulse produced at a servo motor stop.

Parameter No.24

Auto tuning

Automatically adjusts the gain to optimum value if load applied to the servo
motor shaft varies. Higher in performance than MELSERVO-J2 series servo
amplifier.

Chapter 6

Regenerative option

Used when the built-in regenerative resistor of the servo amplifier does not
have sufficient regenerative capability for the regenerative power generated.

Section 12.1.1

Brake unit

Used when the regenerative option cannot provide enough regenerative power.
Can be used with the MR-J2S-500B to MR-J2S-22KB.

Section 12.1.2

Return converter

Used when the regenerative option cannot provide enough regenerative power.
Can be used with the MR-J2S-500B to MR-J2S-22KB.

Section 12.1.3

Torque limit

Servo motor torque can be limited to any value.

Parameters
No.10, 11

Forced stop signal automatic
ON

Forced stop (EM1) can be automatically switched on internally to invalidate it. Parameter No.23

Output signal (DO) forced
output

Output signal can be forced on/off independently of the servo status.
Use this function for output signal wiring check, etc.

Section 4.4
(1) (e)

Test operation mode

JOG operation positioning operation motor-less operation DO forced output Section 4.4

Analog monitor output

Servo status is output in terms of voltage in real time.

Parameter No. 22

MR Configurator
(Servo configuration software)

Using a personal computer, parameter setting, test operation, status display,
etc. can be performed.

Section 12.1.8