1 connection example of control signal system, 1 mr-j2s-700b or less, Signals and wiring – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 45

Advertising
background image

3 - 2

3. SIGNALS AND WIRING

3.1 Connection example of control signal system

POINT

Refer to section 3.5 for the connection of the power supply system and to
section 3.6 for connection with the servo motor.

3.1.1 MR-J2S-700B or less

Servo amplifier

(Note 5)

CN1A

CN1B

(Note 5) SW1

CN1A

CN1B

CN1A

CN1B

CN1A

CN1B

MR-J2S-B

(2 axis)

SW1

Setting: 1

SW1

(Note 11)

SW1

n

(Note 13)

MR-A-TM

(Note 10, 14)
Bus cable (Option)

(Note 1)

CN3

(Note 4)
Personal computer

A

A

15m(49.2ft)
or less

Encoder A-phase pulse
(differential line driver)
Encoder B-phase pulse
(differential line driver)
Encoder Z-phase pulse
(differential line driver)

Plate

2m(6.56ft) or less

(Note 3,4,7)
Forced stop

10k

10k

Analog monitor output
Max. 1mA
Reading in
both directions

Magnetic brake
interlock

Setting: 0

Servo system controller

Cable clamp
(Option)

(Note 10, 14)
Bus cable
(Option)

MR-J2S-B

(3 axis)

(Note 11)

Setting: 2

MR-J2S-B

(n axis)

Setting: n 1

(Note 11)

(Note 12)

1 to 8

(Note 2,6)

(Note15)

10 VDD

20 EM1

3

SG

6

LA

16

LAR

7

LB

17

LBR

8

LZ

18

LZR

4

MO1

1

LG

14 MO2
11

LG
SD

10m(32.81ft) or less

CN3

(Note 5, 8)

13 MBR

5

COM

RA1

When using the forced stop (EM1) or magnetic brake
interlock (MBR), make sure to connect it.

Control common

(Note 9)
MR Configurator
(Servo configuration
software)

Advertising