2 signal explanations, Signals and wiring – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 51

Advertising
background image

3 - 8

3. SIGNALS AND WIRING

3.2.2 Signal explanations
For the I/O interfaces (symbols in I/O column in the table), refer to section 3.4.2.

(1) Connector applications

Connector

Name

Function/Application

CN1A

Connector for bus cable from preceding axis.

Used for connection with the controller or preceding-axis

servo amplifier.

CN1B

Connector for bus cable to next axis

Used for connection with the next-axis servo amplifier or

for connection of the termination connector.

CN2

Encoder connector

Used for connection with the servo motor encoder.

CN3

Communication connector

(I/O signal connector)

Used for connection with the personal computer.

Serves as an I/O signal connector when the personal

computer is not used.

(Note)

CN4

Analog monitor output connector

Used to output analog monitor 1 (MO1) and analog monitor

2 (MO2).

(Note)

CON2 IO signal connector

Used to input a forced stop and output the dynamic brake

interlock(DB), the electromagnetic brake interlock

Note. These connectors are exclusive to the MR-J2S-11KB or more.

(2) I/O signals

(a) Input signal

Connector Pin

No.

Signal

Symbol

7kW

or less

11kW

or more

Function/Application

I/O Division

Forced stop

EM1

CN3

20

CON2

2

Turn EM1 off (open EM1 common) to bring the motor to a

forced stop state, in which the base circuit is shut off and the

dynamic brake is operated.

Turn EM1 on (short EM1 common) in the forced stop state to

reset that state.

DI-1

(b) Output signals

Connector Pin

No.

Signal

Symbol

7kW

or less

11kW

or more

Function/Application

I/O Division

Electromagnetic brake

interlock

MBR

CN3

13

CON2

3

In the servo-off or alarm status, MBR turns off.

DO-1

Dynamic brake

interlock

DB

CON2

4

When using this signal, set 1

in the parameter No. 2.

When the dynamic brake is operated, DB turns off.

DO-1

Encoder A-phase pulse

(Differential line driver)

LA

LAR

CN3

6

CN3

16

CN3

6

CN3

16

Encoder B-phase pulse

(Differential line driver)

LB

LBR

CN3

7

CN3

17

CN3

7

CN3

17

Outputs pulses per servo motor revolution set in parameter

No.38 in the differential line driver system. In CCW rotation

of the servo motor, the encoder B-phase pulse lags the

encoder A-phase pulse by a phase angle of /2.

DO-2

Encoder Z-phase pulse

(Differential line driver)

LZ

LZR

CN3

8

CN3

18

CN3

8

CN3

18

The zero-phase signal of the encoder is output in the

differential line driver system.

DO-2

Analog monitor 1

MO1

CN3

4

CN4

1

Used to output the data set in parameter No.22 to across

MO1-LG in terms of voltage. Resolution 10 bits

Analog

output

Analog monitor 2

MO2

CN3

14

CN4

2

Used to output the data set in parameter No.22 to across

MO2-LG in terms of voltage. Resolution 10 bits

Analog

output

(c) Power supply

Connector Pin

No.

Signal

Symbol

7kW

or less

11kW

or more

Function/Application

Internal power output

for interface

VDD

CN3

10

CON2

15

Driver power output terminal for digital interface.

Used to output 24V 10% to across VDD-COM. Connect with COM.

Permissible current: 80mA

Power input for digital

interface

COM

CN3

5

CON2

18

Driver power input terminal for digital interface.

Used to input 24VDC (200mA or more) for input interface.

Connect with VDD.

Common for digital

interface

SG

CN3

3

CON2

1

Common terminal to VDD and COM. Pins are connected internally.

Separated from LG.

Control common

LG

CN3

1

11

CN4

4

Common terminal to MO1 and MO2.

Shield

SD

Plate

Plate Connect the external conductor of the shield cable.

Advertising