11 control axis selection, Signals and wiring – MITSUBISHI ELECTRIC Merservo MR-J2S- B User Manual

Page 74

Advertising
background image

3 - 31

3. SIGNALS AND WIRING

3.11 Control axis selection

POINT

The control axis number set to SW1 should be the same as the one set to
the servo system controller.

Use the axis select switch (SW1) to set the control axis number for the servo. If the same numbers are set
to different control axes in a single communication system, the system will not operate properly. The
control axes may be set independently of the bus cable connection sequence.
Set the switch to "F" when executing the test operation mode using MR Configurator (servo configuration
software).

Axis select switch (SW1)

1

C

B

A

9

8

7

6

5

4

3

2

0

F

E

D

No.

Description

0

Axis 1

1

Axis 2

2

Axis 3

3

Axis 4

4

Axis 5

5

Axis 6

6

Axis 7

7

Axis 8

8

Not used

9

Not used

A

Not used

B

Not used

C

Not used

D

Not used

E

Not used

F

Test operation mode or
when machine analyzer is used
(Refer to section 6.1.2)

Advertising