3. SIGNALS AND WIRING

3.12.1 Connection example

Wire the power supply/main circuit as shown below so that power is shut off and the servo-on signal
turned off as soon as an alarm occurs, a servo forced stop is made valid, a controller forced stop, or a servo
motor thermal relay alarm is made valid. A no-fuse breaker (NFB) must be used with the input cables of
the power supply.

(Note 1)

Alarm

RA1

Controller

forced stop

RA2

L

1

L

2

L

3

L

11

L

21

VDD

COM

EM1

SG

Servo amplifier

CN2

U

V

W

U

V

W

Dynamic

break

Servo motor

HA-LFS series

M

Encoder

BU

Cooling fan

RA3

24VDC

power supply

MR-JHSCBL M

cable

BV

BW

MC

SK

ON

MC

OFF

Forced

stop

Servo motor

thermal relay

RA3

NFB

MC

Forced stop

OHS2

OHS1

Servo motor
thermal relay

(Note 3)

3-phase
200 to 230V

(Note 2)

P

1

P

(Note 4)

Note 1. Configure up the power supply circuit which switches off the magnetic contactor after detection of alarm occurrence on the

controller side.

2. When using the external dynamic break, refer to section 12.1.4.
3. Cooling fan power supply of the HA-LFS11K2 servo motor is 1-phase. Power supply specification of the cooling fan is different

from that of the servo amplifier. Therefore, separate power supply is required.

4. Always connect P

1

and P. (Factory-wired.) When using the power factor improving DC reactor, refer to section 12.2.4.