4. OPERATION AND DISPLAY

4. OPERATION AND DISPLAY

4.1 When switching power on for the first time

Before starting operation, check the following.

(1) Wiring

(a) A correct power supply is connected to the power input terminals (L

1

, L

2

, L

3

, L

11

, L

21

) of the servo

amplifier.

(b) The servo motor power supply terminals (U, V, W) of the servo amplifier match in phase with the

power input terminals (U, V, W) of the servo motor.

(c) The servo motor power supply terminals (U, V, W) of the servo amplifier are not shorted to the

power input terminals (L

1

, L

2

, L

3

) of the servo motor.

(d) The earth terminal of the servo motor is connected to the PE terminal of the servo amplifier.

(e) Note the following when using the regenerative option, brake unit or power regeneration converter.

1) For the MR-J2S-350B or less, the lead has been removed from across D-P of the control circuit

terminal block, and twisted cables are used for its wiring.

2) For the MR-J2S-500B MR-J2S-700B, the lead has been removed from across P-C of the servo

amplifier built-in regenerative resistor, and twisted cables are used for its wiring.

(f) 24VDC or higher voltages are not applied to the pins of connector CN3.

(g) SD and SG of connector CN3 are not shorted.

(h) The wiring cables are free from excessive force.

(i) CN1A should be connected with the bus cable connected to the servo system controller or preceding

axis servo amplifier, and CN1B should connected with the bus cable connected to the subsequent
axis servo amplifier or with the termination connector (MR-A-TM.)

(2) Axis number

The axis number setting of SW1 should be the same as that of the servo system controller. (Refer to
section 3.11.)

(3) Parameters

On the servo system controller screen or using the MR Configurator (servo configuration software),
make sure that correct values have been set in the parameters.

(4) Environment

Signal cables and power cables are not shorted by wire offcuts, metallic dust or the like.

(5) Machine

(a) The screws in the servo motor installation part and shaft-to-machine connection are tight.

(b) The servo motor and the machine connected with the servo motor can be operated.