SX-200 IP Node

Cabling

The SX-200 EL and SX-200 ML systems use standard male Amphenol 25-pair connectors for
cabling between the system and the main distribution frame (MDF). Cables to all
industry-standard telephones, SUPERSET telephones, and consoles are either 2- or 4-wire
with standard modular connectors.

Cable Lengths

The following rules must be followed for cable lengths between the system and the telephone.
Bridge taps are not permitted.

Cable Lengths Between the PBX and the Telephone

Output Power

Output Voltage

Max Current

+3.3 +/- 1.5%

30.0A

+5.0V +/- 1%

8.0A (Total power of 3.3V and 5.0V not to exceed 100W)

+12.0V +/- 7%

3.0A (Hard Disk Drive)

Cable

Maximum Length

Twisted-pair cable (24 or 26 AWG)

1000 m (3200 ft.)

Quad cable (22 AWG)

50 m (160 ft.)

Modular line cord

3 m (10 ft.)

T1 trunk card

200.5 m (655 ft.)