Specifications

50003510

Revision A

227

Loop Lengths

Loop lengths for various cards are given below:

Card Type

Wire Gauge

(AWG)

Loop Length

DNIC Line Card or DNIC Module
(Connected to Digital Telephone)

(Connected to DNIC Console)

24

26

24

26

1006 m (3300 ft)

1006 m (3300 ft)

1006 m (3300 ft)

1006 m (3300 ft)

ONS Card

22

24

26

3560 m (11700 ft)

2250 m (7400 ft)

1400 m (4600 ft)

ONS Module (SX-200 SPINE)

22

24

26

1784 m (5850 ft)

1128 m (3700 ft)

700 m (2300 ft)

OPS Card

22

24

26

18290 m (60000 ft)

11520 m (37800 ft)

7225 m (23700 ft)

COV Card

22

24

26

2000 m (6600 ft)

1500 m (5000 ft)

1000 m (3300 ft)

E & M Trunk

22

24

26

2715 m (8900 ft)

1708 m (5600 ft)

1068 m (3500 ft)

DID Trunk Card - CO Trunk resistance

na

2240 ohms

LS/GS Trunk Card - CO Trunk resistance

na

1600 ohms

LS/CLASS II Module - CO Trunk resistance

na

1600 ohms

T1 Trunk (cable lengths not loop lengths for 22
gauge wire)

S1 only closed: 0 - 45.8 m (0 - 150 ft)
S2, S3, S4 closed: 45.8 - 137.3 m (150 - 450 ft)
S5, S6, S7 closed: 137.3 - 200 m (450 - 655 ft)

22

These are cable lengths,
not loop lengths. Set DIP
switches on T1 Trunk
card for correct
equalization depending
on cable length between
the T1 Trunk and the
Channel Service Unit
(CSU).