Mitel SX-2000 User Manual

Page 56

Advertising
background image

SX-200 General Information Guide

42

Revision A

50003510

You can have either two or three links to each peripheral bay:

With a MCCIIIEL / ELx control card, the Control Dual FIM Carrier card or the Control Triple
CIM card provides three links per peripheral bay

With an MCCIIIEL control card, the Control Triple FIM Carrier card or the Control Triple
CIM card provides two links per peripheral bay

With an MCCIIIELx control card (installed in a SX-200 ELx cabinet PN 9109-600-002-NA)
the Triple FIM Carrier card or the Control Triple CIM card provides three links per peripheral
bay.

If you provide two links to each bay:

You can have a maximum of seven cabinets in the system

Prior to LIGHTWARE 18 Release 2.0, you could have one bay with two T1 trunk cards
and the other bays with one T1 trunk card to total a maximum of seven T1 trunk cards in
the system

With LIGHTWARE 18 Release 2.0 or greater, you can have a total of 8 T1 links in the
system with a maximum of 2 T1 links per bay

If a T1 trunk card is installed in slot 10 of a bay, you cannot install a peripheral interface
cards in slot 5; if a T1 trunk card is installed in slot 11, you cannot install a peripheral
interface card in slot 6

T1 links from a T1/E1 module on a BCC III also occupy slots 5 and 6 in software only

Calls must be evenly distributed across all bays

Maximum channel blocking ratio is 0.58.

If you provide three links to each bay

You can have a maximum of seven cabinets in the system

Prior to LIGHTWARE 18 Release 2.0, you could have one bay with two T1 trunk cards
and the other bays with one T1 trunk card to total a maximum of seven T1 trunk cards in
the system.

With LIGHTWARE 18 Release 2.0 or greater, you can have a total of 8 T1 links in the
system with a maximum of 2 T1 links per bay.

If a T1 trunk card is installed in slot 10 of a bay, you cannot install a peripheral interface
cards in slot 5; if a T1 trunk card is installed in slot 11, you cannot install a peripheral
interface card in slot 6.

T1 links from a T1/E1 module on a BCC III also occupy slots 5 and 6 in software only.

Note: A manual switch on the Control Triple CIM card controls whether the card will
emulate a Control Dual FIM Carrier card or a Control Triple FIM Carrier card.

Note: As a guideline to achieve a P.0001 grade of service (one failure in 10,000 calls)
for a Bay connected via a Control Triple FIM Carrier, the recommended maximum
calls/hour is 500 based on traffic tables. With a typical call hold time of 2 minutes and 12
seconds the total Erlang rate is 18.33 (660 CCS) for the whole Bay. The half Bay would
therefore be 9.17 Erlangs (330 CCS) at 250 calls/hour. It is important that calls be evenly
distributed across all Bays.