Power-off the drive, Reset the drive – StorageTek 9840 User Manual

Page 106

Advertising
background image

Basic Operations

4-2

Sixth Edition

95741

4. Wait until the drive successfully completes IPL. Note the following:

The “

CC DIAGS

” and “

ASIA DIAGS

” messages indicate that the IPL

diagnostics are active. These messages require no action on your part.

The drive powers on automatically to online mode if drive is operable
and configuration error/s were not encountered.

The drive powers on to offline mode if a configuration error was
encountered and the “

Fix_CfgErr

” message displays; see note.

Memory Err

” or “

Boot Fai

l” may be displayed if an error occurs

early in the IPL sequence. These errors cause the drive to hang; see
note.

Note: If any error displays, go to

Table 7-2 on page 7-3

for a description of

corrective action.

5. Inform the operator when the drive is available and can receive I/O from

the host(s).

Power-off the Drive

Note: Refer to

Chapter 5, “Cartridge Scratch Loader,”

for instructions to power-

off a CSL.

1. Make sure I/O is not active to the drive from any host(s).

2. Unload a tape cartridge, if loaded, and remove it from drive.

3. Power-off the drive:

a. For a desktop unit and/or rack-mountable drive tray, set the

Power

switch on the rear panel to OFF.

b. For a library drive power supply that has a

Power

switch, set the

Power

switch to OFF.

c. For a library drive power supply that does not have a

Power

switch,

disconnect the power supply power cord.

Reset the Drive

Pressing the

IPL

switch resets the drive and reloads drive firmware into drive

memory. (The same process occurs automatically at power-on).

To reset a drive that is already powered on:

1. Make sure a cartridge tape is not loaded in the drive.