Figure 3-2. fibre channel cable connector -4, List, Figure 3-2 on – StorageTek 9840 User Manual

Page 54

Advertising
background image

Inspecting the Equipment

3-4

Sixth Edition

95741

Note: The cable connector is keyed so the cable can only be inserted one way.

The cable acts somewhat like a null modem cable in that the transmit from one
end of the cable connects to the receive at the other end of the cable. The cable
connectors are typically labeled A and B. In addition, one strand of the cable is
labeled (with the vendor name and other information) while the other strand is
unlabeled.

Table 3-1. Fibre Channel Cable (SC to SC Connectors) Part Numbers

Length

Part Number

Meters

Feet

Plenum

1

Riser

2

2

6.6

10800122

10800132

5

16.4

10800123

10800133

10

32.8

10800124

10800134

20

65.6

10800125

10800135

30

98.4

10800126

10800136

50

164

10800127

10800137

100

328.1

10800128

10800138

250

820.2

10800129

10800139

500

1640.4

10800130

10800140

Notes:
1. Plenum cables are designed for installation in air ducts. Plenum materials are

manufactured to meet UL standards for flammability (produce little smoke).

2. Riser cables can be used in computer rooms. Riser cable materials are not classified

according to flammability or toxic gas emissions.